Filter Results By:

Products

Applications

Manufacturers

Open Short

Pinpoint open circuits.


Showing results: 196 - 210 of 257 items found.

  • 4-in-1 OSLT Calibration Kit, DC to 18 GHz, Type-N (f) 50 Ohm

    CK519A - Spanawave Corporation

    The Network Analyzer Calibration Kits with open, short, load, and thru (OSLT) provide the RF components needed to enable stable and accurate error correct measurements. Calibration of a network analyzer using Spanawave's Network Analyzer Calibration Kits allow for precise measurements. The Calibration Kits offer broad test equipment coverage for use with the 8003 Scalar Network Analyzer as well as being compatible with most network analyzers produced by other manufacturers. Spanawave calibration kits yield complete calibrations, as it takes into consideration the three major sources of systematic error correction by one port calibration at both ports.

  • 4-in-1 OSLT Calibration Kit, DC to 18 GHz, Type-N (m) 50 Ohm

    CK518A - Spanawave Corporation

    The Network Analyzer Calibration Kits with open, short, load, and thru (OSLT) provide the RF components needed to enable stable and accurate error correct measurements. Calibration of a network analyzer using Spanawave's Network Analyzer Calibration Kits allow for precise measurements. The Calibration Kits offer broad test equipment coverage for use with the 8003 Scalar Network Analyzer as well as being compatible with most network analyzers produced by other manufacturers. Spanawave calibration kits yield complete calibrations, as it takes into consideration the three major sources of systematic error correction by one port calibration at both ports.

  • 4-in-1 OSLT Calibration Kit, DC to 26.5 GHz, Type-3.5 mm (f) 50 Ohm

    CK521A - Spanawave Corporation

    The Network Analyzer Calibration Kits with open, short, load, and thru (OSLT) provide the RF components needed to enable stable and accurate error correct measurements. Calibration of a network analyzer using Spanawave's Network Analyzer Calibration Kits allow for precise measurements. The Calibration Kits offer broad test equipment coverage for use with the 8003 Scalar Network Analyzer as well as being compatible with most network analyzers produced by other manufacturers. Spanawave calibration kits yield complete calibrations, as it takes into consideration the three major sources of systematic error correction by one port calibration at both ports.

  • 4-in-1 OSLT Calibration Kit, DC to 26.5 GHz, Type-3.5 mm (m) 50 Ohm

    CK520A - Spanawave Corporation

    The Network Analyzer Calibration Kits with open, short, load, and thru (OSLT) provide the RF components needed to enable stable and accurate error correct measurements. Calibration of a network analyzer using Spanawave's Network Analyzer Calibration Kits allow for precise measurements. The Calibration Kits offer broad test equipment coverage for use with the 8003 Scalar Network Analyzer as well as being compatible with most network analyzers produced by other manufacturers. Spanawave calibration kits yield complete calibrations, as it takes into consideration the three major sources of systematic error correction by one port calibration at both ports.

  • 4-in-1 OSLT Calibration Kit, DC to 40 GHz, 2.92 mm (m)

    CK562A - Spanawave Corporation

    The Network Analyzer Calibration Kits with open, short, load, and thru (OSLT) provide the RF components needed to enable stable and accurate error correct measurements. Calibration of a network analyzer using Spanawave's Network Analyzer Calibration Kits allow for precise measurements. The Calibration Kits offer broad test equipment coverage for use with the 8003 Scalar Network Analyzer as well as being compatible with most network analyzers produced by other manufacturers. Spanawave calibration kits yield complete calibrations, as it takes into consideration the three major sources of systematic error correction by one port calibration at both ports.

  • 4-in-1 OSLT Calibration Kit, DC to 50 GHz, 2.4 mm (m)

    CK564A - Spanawave Corporation

    The Network Analyzer Calibration Kits with open, short, load, and thru (OSLT) provide the RF components needed to enable stable and accurate error correct measurements. Calibration of a network analyzer using Spanawave's Network Analyzer Calibration Kits allow for precise measurements. The Calibration Kits offer broad test equipment coverage for use with the 8003 Scalar Network Analyzer as well as being compatible with most network analyzers produced by other manufacturers. Spanawave calibration kits yield complete calibrations, as it takes into consideration the three major sources of systematic error correction by one port calibration at both ports.

  • 4-in-1 OSLT Calibration Kit, DC to 70 GHz, Type-1.85 mm (f)

    CK058F - Spanawave Corporation

    The Network Analyzer Calibration Kits with open, short, load, and thru (OSLT) provide the RF components needed to enable stable and accurate error correct measurements. Calibration of a network analyzer using Spanawave's Network Analyzer Calibration Kits allow for precise measurements. The Calibration Kits offer broad test equipment coverage for use with the 8003 Scalar Network Analyzer as well as being compatible with most network analyzers produced by other manufacturers. Spanawave calibration kits yield complete calibrations, as it takes into consideration the three major sources of systematic error correction by one port calibration at both ports.

  • 4-in-1 OSLT Calibration Kit, DC to 70 GHz, Type-1.85 mm (m)

    CK058M - Spanawave Corporation

    The Network Analyzer Calibration Kits with open, short, load, and thru (OSLT) provide the RF components needed to enable stable and accurate error correct measurements. Calibration of a network analyzer using Spanawave's Network Analyzer Calibration Kits allow for precise measurements. The Calibration Kits offer broad test equipment coverage for use with the 8003 Scalar Network Analyzer as well as being compatible with most network analyzers produced by other manufacturers. Spanawave calibration kits yield complete calibrations, as it takes into consideration the three major sources of systematic error correction by one port calibration at both ports.

  • Gas & Flame Detection System

    Syntel - Teledyne Gas & Flame Detection

    Syntel is an addressable loop system suitable for use in zone 1 and 2 hazardous areas. The complete addressable loo is fault tolerant operating normally with a short or open circuit. Syntel does not have a CPU, so there is no common failure point. It includes a standard OPC interface and can also be supplied by Modbus allowing easy integration with third party systems.Syntel stores alarm and calibration information in distributed non-volatile memory, hence there is no reliance on a centralized system.Syntel is ideal for installations where there is the possibility for future expansion. The system architecture allows very low cost expansion as cable runs to a central location are not needed.

  • Switch Modules - 32 Single Pole Relays Arranged as a 16x2 Matrix

    JX32/AB-1 - Cytec Corp.

    This module has 32 single pole relays arranged as a 16x2 matrix as shown in the figure to the left. The matrix may be operated and wired individually for up to 16 16x2's per chassis, or jumpered to the backplane to form up to a 256x2 matrix. It is available with Type S or M reed relays for high speed, long life application. These modules are usually used for 2 wire testing where high and low meter leads must be switched between any two points. Often used for 2 wire LCR meter measurements, cable testing, or open / short testing in a variety of applications.

  • Switch Modules - 16 Single Pole Relays Arranged as an 8x2 Matrix

    JX16/AB-1 - Cytec Corp.

    This module has 16 single pole relays arranged as an 8x2 matrix as shown in the figure to the left. The matrix may be operated and wired individually for up to 16 8x2's per chassis, or jumpered to the backplane to form up to a 128x2 matrix. It is available with Type S or M reed relays for high speed, long life application. These modules are usually used for 2 wire testing where high and low meter leads must be switched between any two points. Often used for 2 wire LCR meter measurements, cable testing, or open / short testing in a variety of applications.

  • Solar Array Simulator DC Power Supply

    62000H-S - Chroma Systems Solutions, Inc.

    Solar Array Simulator DC Power Supplies by Chroma provide programmable simulation of Voc (open circuit voltage) up to 1800V and Isc (short circuit current) up to 30A. The 62000S-H series provides an industry leading power density in a small 3U high package. The Solar Array Simulator is highly stable and has a fast transient response design, which are both advantages to MPPT performance evaluation on PV inverter devices.

  • Lan Cable Tester

    185 LCT - Standard Electric Works Co., Ltd

    ● Designed for RJ45/RJ11 modular cables, 10/100 base-T cable and Token Ring cable.● The LAN cable tester can verify cable continuity, open, short circuit and miss-wired.● The remote receiving unit is available for installed cables far away either on the wall plates or on the patch panels.● Auto and manual scan functions.● Ground wire test. ● Lock status function.● Buzzer sound warning for wire status.● Display : LED indication for wire status.

  • Automated DC Parametric Curve Tracer

    MultiTrace - Robson Technologies, Inc.

    MultiTrace curve tracer is a mid-sized benchtop model supporting pin counts from 216-625 pins and includes the PGA-625 fixture as a standard interface. MultiTrace supports a wide range of test applications: Failure analysis, Reliability testing, Counterfeit device analysis, Nondestructive electrical counterfeit test, Opens, shorts leakage testing (OSL), Post decap electrical inspection, Optical fault localization, ESD testing, Latch-up testing, Supply current measurements, and more!

  • Low Voltage Test & Measurement

    Greenlee Tools

    Low voltage testing is able to catch errors such as shorts and opens by applying current to a wire and measuring the voltage. The wire will have a current affected by several factors including resistance and components. If the wire is connected correctly, the test will read low resistance. That means current is flowing through the wire as expected and reaching the required connections. If the tester reads high resistance it means something is impeding the current from reaching its destination. This could be caused by a number of causes.

Get Help